Pathophysiology of esophageal impairment due to button battery ingestion.

Photo from wikipedia

BACKGROUND The increased use of button batteries with high energy densities in devices of daily life presents a high risk of injury, especially for toddlers and young children. If an… Click to show full abstract

BACKGROUND The increased use of button batteries with high energy densities in devices of daily life presents a high risk of injury, especially for toddlers and young children. If an accidental ingestion of a button battery occurs, this foreign body can become caught in the constrictions of the esophagus and cause serious damage to the adjacent tissue layers. The consequences can be ulcerations, perforations with fistula formation and damage to the surrounding anatomical structures. In order to gain a better understanding of the pathophysiology after ingestion, we carried out systematic studies on fresh preparations of porcine esophagi. METHODS The lithium button battery type CR2032, used most frequently in daily life, was exposed in preparations of porcine esophagi and incubated under the addition of artificial saliva at 37 °C. A total of eight esophagi were analysed by different methods. Measurements of the pH value around the battery electrodes and histological studies of the tissue damage were carried out after 0.5-24 h exposure time. In addition, macroscopic time-lapse images were recorded. Measurements of the battery voltage and the course of the electric current supplemented the experiments. FINDINGS The investigations showed that the batteries caused an electrolysis reaction in the moist environment. The positive electrode formed an acidic and the negative electrode a basic medium. Consequently, a coagulation necrosis at the positive pole, and a deep colliquation necrosis at the minus pole occurred. After an exposure time of 12 h, tissue damage caused by the lye corrosion was observed on the side of the negative electrode up to the lamina muscularis. The corrosion progressed up to the final exposure time of 24 h, but the batteries still had sufficient residual voltage, such that further advancing damage would be expected. CONCLUSIONS Button battery ingestion in humans poses an acute life-threatening danger and immediate endoscopic removal of the foreign body is essential. After only 2 h exposure time, significant damage to the tissue could be detected, which progressed continuously to complete esophageal perforation. The primary prevention of battery ingestion is therefore of particular importance.

Keywords: battery ingestion; button battery; battery; ingestion; damage

Journal Title: International journal of pediatric otorhinolaryngology
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.