Background Pulmonary vein isolation (PVI) modulates the intrinsic cardiac autonomic nervous system (ANS). We evaluated the impact of PVI on 5 non-invasive autonomic tests. Methods Thirty patients (76% male, mean… Click to show full abstract

Background Pulmonary vein isolation (PVI) modulates the intrinsic cardiac autonomic nervous system (ANS). We evaluated the impact of PVI on 5 non-invasive autonomic tests. Methods Thirty patients (76% male, mean age 60.37 ± 9.02 years) with paroxysmal atrial fibrillation (AF) underwent cryoballoon-guided PVI. Five autonomic tests were performed 24hrs before and after PVI (N = 30) and repeated after 6months (N = 22). Parasympathetic function was measured by heart rate (HR) variability during deep breathing (E/I ratio, I-E difference), Valsalva maneuver (Valsalva-ratio) and head-up tilt test (30/15 ratio). Sympathetic function was measured by systolic BP response to sustained handgrip and 10’ tilting and by diastolic BP response to cold water. Results 24hrs after PVI, baseline HR increased from 57.93 ± 9.06 bpm to 71.10 ± 12.75 bpm (p < 0.001). At 6 months, baseline HR was lower than immediately post-PVI (62.59 ± 7.89 vs 71.36 ± 13.58 bpm, p = 0.032) but still higher in comparison to pre-PVI (62.59 ± 7.89 vs 57.09 ± 8.80 bpm, p < 0.001). No differences were seen in baseline BP and parasympathetic tests acutely and at 6months. Besides an acute lowering in systolic BP increase during handgrip test, all sympathetic tests remained unchanged. Conclusions An acute HR increase attenuated at 6months and an acute lowered systolic BP response to sustained handgrip were the only changes after cryoballoon-guided PVI. Non-invasive autonomic tests seem therefore not appropriate to evaluate the autonomic modulatory effect of PVI, either due to a too limited sensitivity or a too localized effect of PVI to influence test results.

Keywords: cryoballoon guided; invasive autonomic; non invasive; pulmonary vein; pvi; autonomic tests

Journal Title: Indian Pacing and Electrophysiology Journal
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.