LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Arterial Pulsatility and Circulating von Willebrand Factor in Patients on Mechanical Circulatory Support.

Photo from wikipedia

BACKGROUND The main risk factor for bleeding in patients with continuous-flow mechanical circulatory support (CF-MCS) is the acquired von Willebrand factor (VWF) defect related to the high shear-stress forces developed… Click to show full abstract

BACKGROUND The main risk factor for bleeding in patients with continuous-flow mechanical circulatory support (CF-MCS) is the acquired von Willebrand factor (VWF) defect related to the high shear-stress forces developed by these devices. Although a higher bleeding rate has been reported in CF-MCS recipients who had reduced pulsatility, the relation between pulsatility and the VWF defect has never been studied. OBJECTIVES The purpose of this study was to investigate the relation between pulsatility and VWF under CF-MCS. METHODS We assessed the effect of 2 CF-MCS on VWF multimer degradation in a mock circulatory loop (model 1). Using these devices, we investigated in a dose-effect model (model 2) 3 levels of pulsatility in 3 groups of swine. In a cross-over model (model 3), we studied the effects of sequential changes of pulsatility on VWF. We reported the evolution of VWF multimerization in a patient undergoing serial CF-MCS and/or pulsatile-MCS. RESULTS We demonstrated the proteolytic degradation of VWF multimers by high shear CF-MCS in a circulatory loop without pulsatility. We observed both in swine models and in a patient that the magnitude of the VWF degradation is modulated by the pulsatility level in the high shear-stress level condition, and that the restoration of pulsatility is a trigger for the endothelial release of VWF. CONCLUSIONS We demonstrated that the VWF defect reflects the balance between degradation induced by the shear stress and the endothelial release of new VWF triggered by the pulsatility. This modulation of VWF levels could explain the relationship between pulsatility and bleeding observed in CF-MCS recipients. Preservation of pulsatility may be a new target to improve clinical outcomes of patients.

Keywords: mcs; mechanical circulatory; pulsatility; model; factor; vwf

Journal Title: Journal of the American College of Cardiology
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.