LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

One-pot, direct glucose detection in human whole blood without using a dilution factor by a magnetic nanozyme with dual enzymatic activity

Photo from wikipedia

Abstract The necessity of sample pretreatment, the limited absorbance variation in the concentration range of calibration plot are the common restrictions of the colorimetric glucose sensors used with the complex… Click to show full abstract

Abstract The necessity of sample pretreatment, the limited absorbance variation in the concentration range of calibration plot are the common restrictions of the colorimetric glucose sensors used with the complex samples. A calibration plot in a concentration range far below the common level of complex biological sample mostly involves to use a high dilution factor for finding the actual glucose level in the complex sample. Glucose oxidase immobilized-Au nanoparticle attached-magnetic SiO2 (GOx@Au@MagSiO2) microspheres were proposed as a new magnetic nanozyme, allowing one-pot and direct determination of glucose concentration in human whole blood without using a sample pretreatment and a high dilution factor. As an unusual approach which is not coherent with the common strategy followed for colorimetric determination of blood glucose level, a calibration plot based on the common range of human whole blood (i.e. 2.8–38.9 mM) is generated with the synthesized nanozyme. GOx was directly linked onto Au nanoparticles (Au NPs) immobilized on the magnetic SiO2 microspheres via a simple protocol, using the thiol groups of its cysteine residues, as a unique property of GOx’s, for the first time. The activity of free GOx could be highly preserved by the selected immobilization protocol. GOx@Au@MagSiO2 microspheres exhibited peroxidase-like activity due to Au NPs immobilized on the magnetic microspheres, together with the glucose oxidation ability originated from GOx linked to Au NPs. The nanozyme was efficiently used for one-pot, direct determination of glucose level in human whole blood in the concentration range of 50–700 mg/dL (i.e. 2.8–38.9 mM).

Keywords: human whole; gox; dilution factor; blood; one pot; whole blood

Journal Title: Journal of Alloys and Compounds
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.