LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Predicting physician burnout using clinical activity logs: Model performance and lessons learned

Photo by jordanmcdonald from unsplash

BACKGROUND Burnout is a significant public health concern affecting more than half of the healthcare workforce; however, passive screening tools to detect burnout are lacking. We investigated the ability of… Click to show full abstract

BACKGROUND Burnout is a significant public health concern affecting more than half of the healthcare workforce; however, passive screening tools to detect burnout are lacking. We investigated the ability of machine learning (ML) techniques to identify burnout using passively collected electronic health record (EHR)-based audit log data. METHOD Physician trainees participated in a longitudinal study where they completed monthly burnout surveys and provided access to their EHR-based audit logs. Using the monthly burnout scores as the target outcome, we trained ML models using combinations of features derived from audit log data-aggregate measures of clinical workload, time series-based temporal measures of EHR use, and the baseline burnout score. Five ML models were constructed to predict burnout as a continuous score: penalized linear regression, support vector machine, neural network, random forest, and gradient boosting machine. RESULTS 88 trainee physicians participated and completed 416 surveys; >10 million audit log actions were collected (Mean [Standard Deviation]=25,691 [14,331] actions per month, per physician). The workload feature set predicted burnout score with a mean absolute error (MAE) of 0.602 (95% Confidence Interval (CI), 0.412-0.826), and was able to predict burnout status with an average AUROC of 0.595 (95% CI 0.355-0.808) and average accuracy 0.567 (95% CI 0.393-0.742). The temporal feature set had a similar performance, with MAE 0.596 (95% CI 0.391-0.826), and AUROC 0.581 (95% CI 0.343-0.790). The addition of the baseline burnout score to the workload features improved the model performance to a mean AUROC of 0.829 (95% CI 0.607-0.996) and mean accuracy of 0.781 (95% CI 0.587-0.936); however, this performance was not meaningfully different than using the baseline burnout score alone. CONCLUSIONS Current findings illustrate the complexities of predicting burnout exclusively based on clinical work activities as captured in the EHR, highlighting its multi-factorial and individualized nature. Future prediction studies of burnout should account for individual factors (e.g., resilience, physiological measurements such as sleep) and associated system-level factors (e.g., leadership).

Keywords: burnout using; burnout score; performance; model performance; burnout

Journal Title: Journal of biomedical informatics
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.