LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Objective measurement of Inferior-Directed stiffness in glenohumeral joint using a specially designed robotic device in healthy shoulders; Within- and Between-Session reliability.

Photo from wikipedia

Clinical assessment of capsuloligamentous structures of the glenohumeral joint has been qualitative and subjective in nature, as demonstrated by limited intra- and inter-rater reliability. Robotic devices were utilized to develop… Click to show full abstract

Clinical assessment of capsuloligamentous structures of the glenohumeral joint has been qualitative and subjective in nature, as demonstrated by limited intra- and inter-rater reliability. Robotic devices were utilized to develop a clinically objective measurement technique for glenohumeral joint stiffness. The purpose of this study was to quantify the amount of inferior-direction stiffness of the glenohumeral joint using a safe clinical device in the asymptomatic individuals, and to determine between trial and between session reliability of the robotic device. Twenty healthy subjects were recruited via convenience sampling. Inferior-directed translation and applying force were measured using displacement and force sensors of a robotic device. The stiffness values were calculated as the mean of the slopes of the linear portions of the force-displacement curves for the cycles obtained after familiarization and preconditioning. Four trials for each measurement occasion were averaged to determine the stiffness value for each subject in one session. Repeatability of glenohumeral joint stiffness measurements for between trials and between two sessions was determined using intraclass correlation values and standard error of the measurements. The mean stiffness value was 1.50 N/mm (±0.40) and 1.52 N/mm (±0.40), respectively. The robotic device for stiffness assessment was reliable for repeated measures of stiffness in one session, and between sessions with ICC equal 0.96 (95% CI 0.93-0.98), and 0.97 (95% CI 0.95-0.99), respectively. The SEM between the trials was in each session 0.08 N/mm. The results of this study provide that our robotic technique for quantifying glenohumeral joint stiffness is precise and reproducible.

Keywords: stiffness; robotic device; session; glenohumeral joint; device

Journal Title: Journal of biomechanics
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.