LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Inferior vena cava collapsibility detects fluid responsiveness among spontaneously breathing critically‐ill patients

Photo by toasteronyourleft from unsplash

Purpose: Measurement of inferior vena cava collapsibility (cIVC) by point‐of‐care ultrasound (POCUS) has been proposed as a viable, non‐invasive means of assessing fluid responsiveness. We aimed to determine the ability… Click to show full abstract

Purpose: Measurement of inferior vena cava collapsibility (cIVC) by point‐of‐care ultrasound (POCUS) has been proposed as a viable, non‐invasive means of assessing fluid responsiveness. We aimed to determine the ability of cIVC to identify patients who will respond to additional intravenous fluid (IVF) administration among spontaneously breathing critically‐ill patients. Methods: Prospective observational trial of spontaneously breathing critically‐ill patients. cIVC was obtained 3 cm caudal from the right atrium and IVC junction using POCUS. Fluid responsiveness was defined as a ≥ 10% increase in cardiac index following a 500 ml IVF bolus; measured using bioreactance (NICOM™, Cheetah Medical). cIVC was compared with fluid responsiveness and a cIVC optimal value was identified. Results: Of the 124 participants, 49% were fluid responders. cIVC was able to detect fluid responsiveness: AUC = 0.84 [0.76, 0.91]. The optimum cutoff point for cIVC was identified as 25% (LR + 4.56 [2.72, 7.66], LR‐ 0.16 [0.08, 0.31]). A cIVC of 25% produced a lower misclassification rate (16.1%) for determining fluid responsiveness than the previous suggested cutoff values of 40% (34.7%). Conclusion: IVC collapsibility, as measured by POCUS, performs well in distinguishing fluid responders from non‐responders, and may be used to guide IVF resuscitation among spontaneously breathing critically‐ill patients. HIGHLIGHTSIVC collapsibility, as measured by POCUS, is able to detect fluid responsiveness.Use of a passive leg raise did not improve detection of fluid responsiveness.The optimum cutoff point for IVC collapsibility is cIVC = 25%.cIVC, measured by POCUS may be used to direct fluid resuscitation.

Keywords: civc; collapsibility; fluid responsiveness; responsiveness; spontaneously breathing

Journal Title: Journal of Critical Care
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.