LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Mixed polymeric systems: New ophthalmic viscosurgical device created by mixing commercially available devices.

Photo by cdc from unsplash

PURPOSE To evaluate the rheological properties of mixtures of different commercially available ophthalmic viscosurgical devices (OVDs) containing sodium hyaluronate and chondroitin sulfate. SETTING Eye Clinic, University of Trieste, Trieste, Italy.… Click to show full abstract

PURPOSE To evaluate the rheological properties of mixtures of different commercially available ophthalmic viscosurgical devices (OVDs) containing sodium hyaluronate and chondroitin sulfate. SETTING Eye Clinic, University of Trieste, Trieste, Italy. DESIGN Laboratory study. METHODS Blends were obtained combining a superviscous cohesive OVD (Healon GV [sodium hyaluronate 1%]) and a medium-viscosity dispersive OVD (Viscoat [sodium hyaluronate 3.0%-chondroitin sulfate 4.0%]). The 2 substances were combined in different ratios, and the rheological characteristics were analyzed to find the optimum proportion. A new viscous dispersive OVD, Discovisc (hyaluronic acid 1.6%-chondroitin sulfate 4.0%) was evaluated for comparison. The storage modulus, loss modulus, crossover point, complex viscosity, shear viscosity, and pseudoplasticity were studied. RESULTS The rheological properties of the mixed solution (1:1 and 3:1) showed intermediate characteristics in comparison with the 2 original substances, characterized by a viscosity comparable to that of the superviscous cohesive OVD, but at a higher shear rate (similar to the medium-viscosity dispersive OVD). The new viscous dispersive OVD performed similarly to the medium-viscosity dispersive OVD at low shear rates but was comparable to the superviscous cohesive OVD at high shear rates. CONCLUSIONS The mixture of dispersive and cohesive rheological properties in a single OVD might be an advantage during cataract surgery.

Keywords: viscosity; ophthalmic viscosurgical; dispersive ovd; ovd; rheological properties; commercially available

Journal Title: Journal of cataract and refractive surgery
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.