Abstract In this study, the performance of continuous fed upflow anaerobic microbial fuel cell operated with surgical cotton industry wastewater was investigated at different Organic Loading Rate (OLR). The potency… Click to show full abstract
Abstract In this study, the performance of continuous fed upflow anaerobic microbial fuel cell operated with surgical cotton industry wastewater was investigated at different Organic Loading Rate (OLR). The potency of power generation, COD and TSS removal efficiency was determined. The highest TCOD and SCOD removal of 78.8% and 69%, respectively was accomplished at an optimum OLR of 1.9 gCOD/L d. A 62% TSS removal efficiency was obtained, with an initial TSS concentration of wastewater as 970 ± 70 mg/L. The maximum power density 116.03 mW/m2 (2.2 W/m3) and corresponding coulombic efficiency of 17.8% was achieved at the OLR of 1.9 gCOD/L/d while treating surgical cotton industry waste water.
               