LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Black phosphorene modified glassy carbon electrode for the sensitive voltammetric detection of rutin

Photo from wikipedia

Abstract As a common flavonoid glycoside, rutin owns excellent physiologic activities and has been widely used in clinical chemistry and human health. Therefore the establishment of sensitive and reliable methods… Click to show full abstract

Abstract As a common flavonoid glycoside, rutin owns excellent physiologic activities and has been widely used in clinical chemistry and human health. Therefore the establishment of sensitive and reliable methods for rutin determination is highly important. Black phosphorene (BP) nanosheet modified glassy carbon electrode (GCE) was fabricated by using poly(3,4–ethylenedioxythiophene)–poly(styrenesulfonate) (PEDOT:PSS) as the film and the stabilizer. The incorporation of BP with PEDOT:PSS resulted in a stable nanocomposite (BP–PEDOT:PSS) and its performance were characterized by SEM, EDS and Raman. BP–PEDOT:PSS/GCE showed excellent conductivity and stability, which was applied for the sensitive voltammetric determination of rutin, a commonly used electroactive drug. On cyclic voltammogram a pair of well–defined redox peak of rutin could be obviously observed with enhanced voltammetric response, which could be due to the presence of BP nanosheet that accelerated the electrode reaction. Electrochemical parameters were calculated with the electron transfer coefficient (α) as 0.55 and the apparent heterogeneous electron transfer rate constant (ks) as 4.22 s−1. Under the selected conditions differential pulse voltammetric oxidation peak current of rutin showed linear dependence on its concentration within two sections of 0.02–15.0 μmol/L and 15.0–80.0 μmol/L with a low detection limit of 0.007 μmol/L (3S0/S). Rutin tablet samples were successfully examined by the as-proposed method with satisfactory results, showing the practical applications.

Keywords: glassy carbon; modified glassy; chemistry; black phosphorene; rutin; carbon electrode

Journal Title: Journal of Electroanalytical Chemistry
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.