LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Variability of human-annotations of 12-lead ECG features collected using a web system: Students vs. practitioners

Photo from wikipedia

Introduction: The electrocardiogram (ECG) is often interpreted incorrectly with up to 33% of interpretations containing a significant error. The difficulty in ECG interpretation is two-fold; 1) it demands an extensive… Click to show full abstract

Introduction: The electrocardiogram (ECG) is often interpreted incorrectly with up to 33% of interpretations containing a significant error. The difficulty in ECG interpretation is two-fold; 1) it demands an extensive knowledge of cardiac physiology, and 2) the ECG inflates cognitive workload due to the complex nature of its presentation. To make a diagnosis, the reader is required to measure ECG features in order to contrast these annotations with diagnostic criteria. Whilst signal processing algorithms can provide automated measurements, they are often imprecise. Based on these observations, a web-based system was developed to allow the interpreter to measure and input their own ECG annotations. These annotations are then processed by a rule-based algorithm, which presents a set of suggested diagnoses.However, imprecise and inconsistent human annotations would affect both the reader's diagnostic decision making and also the accuracy of the diagnoses suggested by the algorithm (junk in = junk out). Our study measures the variability of manual annotations collected using our web system. Clinical physiology students (n = 10) and medical practitioners (n = 11) participated in our study.Results: Annotations for the same ECG are as follows (all participants = A, students = S, medical practitioners = P):Heart Rate (A[mean = 89.39 bpm, SD = 9.95], S[mean = 88.7 bpm, SD = 4.27], P[mean = 91.4 bpm, SD = 14.68], p = 0.73), P-wave duration (A[mean = 0.08 s, SD = 0.02], S[mean = 0.09 s, SD = 0.03], P[mean = 0.08 s, SD = 0.01], p = 0.39), P-wave amplitude (A[mean = 0.18 mv, SD = 0.04], S[mean = 0.19 mv, SD = 0.05], P[mean = 0.18 mv, SD = 0.3], p = 0.38), P-R interval (A[mean = 0.16 s, SD = 0.04], S[mean = 0.18 s, SD = 0.05], P[mean = 0.16 s, SD = 0.03], p = 0.49), cardiac axis (A[mean = 58.11°, SD = 13.23], S[mean = 60°, SD = 0], P[mean = 51.5°, SD = 18.8], p = 0.46), Q-T interval (A[mean = 0.32 s, SD = 0.14], S[mean = 0.41 s, SD = 0.06], P[mean = 0.24 s, SD = 0.17], p < 0.01), R-R interval (A[mean = 0.63 s, SD = 0.21], S[mean = 0.72 s, SD = 0.13], P[mean = 0.53 s, SD = 0.27], p = 0.06) and QTc (A[mean = 0.4 s, SD = 0.15], S[mean = 0.48 s, SD = 0.09], P[mean = 0.33 s, SD = 0.2], p = 0.02).Discussion: Students annotated more features (5/8) with less variance. Students annotate interval measurements with 47% less variation than medical practitioners (Σ interval measurement; students SD = 0.36, practitioners SD = 0.68). Students also had less variation in measuring heart rate, P-wave amplitude and cardiac axis. Two of the annotated features (QT-interval and QTc) from both cohorts were statistically different (p ≤ 0.05).Conclusion: In order to make an accurate diagnosis precise ECG annotations are required. This study determined the variability of manual ECG annotations on a cohort containing both students and practitioners.

Keywords: mean; students practitioners; system; ecg; physiology; mean mean

Journal Title: Journal of Electrocardiology
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.