Short-chain chlorinated paraffins (SCCPs) are produced in high volume and have the high potential to pose a threat to human health. However, little information is available for SCCP contamination in… Click to show full abstract
Short-chain chlorinated paraffins (SCCPs) are produced in high volume and have the high potential to pose a threat to human health. However, little information is available for SCCP contamination in human blood/plasma/serum, mainly due to the difficulty of sample preparation and quantitative analysis. A method using high resolution gas chromatography coupled with electron capture negative ionization low resolution mass spectrometry (HRGC-ECNI/LRMS) was developed and validated to measure SCCPs in human plasma. The pretreatment process included protein denaturation and lipid elimination, liquid-liquid extraction with a mixture of n-hexane/dichloromethane (1:1, V/V), and cleanup on a multi-layer silica column. The blank controls, including procedural blank, vacuum blood collection tube blank, and instrumental blank, were the most pivotal points for the reliable analysis of SCCPs. The average value of procedural blanks was 9.0ng/g; and the method detection limit (MDL), calculated as the sum of the average procedural blank value and 3 times of the standard deviation of the procedural blanks, was 12.6ng/g plasma. The validated method was applied to measure the concentrations of the total SCCPs (∑SCCPs) in 50 plasma samples from a general population. The measured plasma concentrations of ∑SCCPs ranged from
               
Click one of the above tabs to view related content.