Evaluation of the agreement of optical biometry and Scheimpflug corneal topography with different axial lengths.

Photo from wikipedia

PURPOSE To compare anterior segment parameters evaluated with optical low coherence reflectometry and combined Scheimpflug-Placido disc topography in eyes with different axial lengths. METHODS Deux cent quatre patients were divided… Click to show full abstract

PURPOSE To compare anterior segment parameters evaluated with optical low coherence reflectometry and combined Scheimpflug-Placido disc topography in eyes with different axial lengths. METHODS Deux cent quatre patients were divided into 3 groups according to their axial lengths. Central corneal thickness (CCT), anterior chamber depth (AD), mean keratometry value (K mean) and white-to-white distances (WTW) obtained from both devices were compared. All measurements were performed 3 times and averaged. RESULTS In group 1, a significant difference was detected between the two devices for CCT, WTW and Kmean measurements (P<0.001, P<0.001, p:0.005 respectively). In group 2, a significant difference was detected between the two devices for WTW measurement (P<0.001). In group 3, a significant difference was detected between the two devices for CCT and WTW measurement (P<0.001, P<0.001 respectively). In the Bland-Altman analysis, there was no match for Kmean obtained with both devices in group 1. In group 2, there was no agreement for AD obtained with both devices. In group 3, there was no match for AD, WTW or Kmean values obtained with both devices. CONCLUSION Some anterior segment parameters are not suitable for interchangeability in eyes with different axial lengths evaluated by Lenstar and Sirius anterior segment imaging systems. When planning critical surgery and treatment, more attention should be paid to measurements in eyes of different axial lengths.

Keywords: topography; obtained devices; corneal; different axial; group; axial lengths

Journal Title: Journal francais d'ophtalmologie
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.