LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Experimental repeatability, sensitivity, and reproducibility of force and strain measurements from within the periodontal ligament space during ex vivo swine tooth loading.

The Periodontal Ligament (PDL) is a complex connective tissue that anchors a tooth to the surrounding alveolar bone. The small size and complex geometry of the PDL space within an… Click to show full abstract

The Periodontal Ligament (PDL) is a complex connective tissue that anchors a tooth to the surrounding alveolar bone. The small size and complex geometry of the PDL space within an intact tooth-PDL-bone complex (TPBC) limits strain measurements. An in-fiber Bragg grating (FBG) sensor offers potential for such measurements due to its small size. This work defines an experimental procedure where strain and force were measured during quasi-static, apically directed, displacement-controlled tests on swine premolar crowns. Specifically, the: inter-TPBC, intra-TPBC, and long-term repeatability after a preconditioned state was objectively identified; sensitivity to preload magnitude, TPBC alignment, and sensor depth; and reproducibility within a TPBC was determined. Data clustering was used to determine the appropriate number of preconditioning trials, ranging from one to seven. Strain and force measurements showed intra-TPBC repeatability with average adjusted root mean square from the median of 28.9% of the peak strain and 4.5% of the peak force measurement. A Mann-Whitney U test generally found statistically significant differences in peak strain and force measurements between the left and right sides, suggesting a lack of inter-TPBC repeatability. Using a Friedman test, it was shown that peak strain measures were sensitive to the TPBC alignment and sensor depth, while peak force measures were sensitive to the preload and TPBC alignment. A Friedman test suggested reproducible strain and force measurements when the FBG was replaced within the same TPBC and the preload, alignment, and sensor depth were controlled.

Keywords: periodontal ligament; strain measurements; repeatability; force; strain; tpbc

Journal Title: Journal of the mechanical behavior of biomedical materials
Year Published: 2021

Link to full text (if available)