LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Comparative investigation on building energy performance of double skin façade (DSF) with interior or exterior slat blinds

Photo from wikipedia

Abstract Advanced passive control technologies attract a great deal of attention by architects and engineers as a way of achieving both high indoor environmental quality and energy efficient buildings. This… Click to show full abstract

Abstract Advanced passive control technologies attract a great deal of attention by architects and engineers as a way of achieving both high indoor environmental quality and energy efficient buildings. This study investigates the thermal and daylighting effects of a double skin facade (DSF) system with interior and exterior blinds. A buffer type DSF and slat type blinds are used for this comparative study. To investigate thermal and daylighting effects of three passive control models, evaluation of annual heating, cooling, and lighting loads is conducted using a widely-accepted whole building energy modeling program, EnergyPlus. A simulated DSF model is developed using the air-flow network (AFN) model in EnergyPlus and calibrated against measured data from an experimental DSF facility installed to an office building in Daejeon, South Korea. After a proper calibration of the simulated DSF model, the impact of blinds in the cavity of the DSF is also evaluated by adopting a slat blind model in EnergyPlus. For exterior and interior blind models, the simulated DSF model is modified by removing a DSF box and adding slat blinds at inner and outer surfaces of the windows. A Radiance-based daylighting simulation program, Daysim, is used to evaluate daylighting aspects of blinds and lighting controls within an office building with simulated DSF, interior blind, and exterior blind models. Generated lighting and blind raise/lower control schedules from Daysim are used as input values in EnergyPlus for annual thermal and lighting load calculations. In addition, the impact of natural ventilation to reduce trapped hot air within the cavity of the DSF box is considered in this study during a cooling period only for the DSF model. Results indicate that the simulated DSF model can save up to 40%, 2%, and 5% for heating, cooling, and total loads, respectively, when compared to the baseline (i.e., no passive technologies) without any blinds or controls. With the combination of the daylight-based dimming control based on the indoor illuminance levels and the blind raise/lower control, the simulated DSF and the exterior blind models could potentially reduce the building thermal loads and lighting energy consumption by around 27–52%., respectively.

Keywords: dsf; energy; control; model; simulated dsf; dsf model

Journal Title: Journal of Building Engineering
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.