Abstract Debonding of fiber-reinforced polymers (FRP) from the concrete substrate is a major concern that compromises the effectiveness of FRP-strengthening. The intermediate-crack (IC) debonding and concrete cover separation (CCS) are… Click to show full abstract

Abstract Debonding of fiber-reinforced polymers (FRP) from the concrete substrate is a major concern that compromises the effectiveness of FRP-strengthening. The intermediate-crack (IC) debonding and concrete cover separation (CCS) are the two main types of debonding failure of FRP-strengthened beams. Multiple factors may affect and lead to any of these two debonding failure modes. In this paper, the influence of shear-span/depth ratio (av/ds) on the ultimate capacity and failure mode of FRP-strengthened beams is explored. A total of 14 beams comprised of 10 strengthened in flexure with carbon FRP (CFRP) sheets along with 4 control beams were investigated covering varying av/ds ratios in the range of 1.5 to 7. For all the strengthened beams, the CFRP sheets were externally bonded to the soffit of the beams and extended close to the supports. The beams were simply supported and were tested in four-point bending. The results of this study showed clear effect of av/ds ratio on the type of debonding failure and strain at failure. For the beams tested in this study, a threshold value of av/ds ratio of 3.0 was identified at and below which the failure mode shifted from IC debonding to CCS. The results also indicated that all beams with CCS failed at the same shear load irrespective of av/ds ratio. Comparison of experimental results with provisions of various design codes and guidelines to guard against debonding failures clearly shows the need for improved prediction of CCS failure.

Keywords: shear span; frp strengthened; ratio; span depth; strengthened beams; failure

Journal Title: Journal of building engineering
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.