LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Rapid analysis of benzalkonium chloride using paper spray mass spectrometry

Photo from wikipedia

Graphical abstract Figure. No Caption available. HighlightsPaper spray mass spectrometry (PS‐MS), a novel mass spectrometry technique, was applied.PS‐MS can quickly obtain the composition of BACs in various samples (only 10… Click to show full abstract

Graphical abstract Figure. No Caption available. HighlightsPaper spray mass spectrometry (PS‐MS), a novel mass spectrometry technique, was applied.PS‐MS can quickly obtain the composition of BACs in various samples (only 10 s).Accurate and high throughput quantitative analysis of BACs can be achieved using PS‐MS.Reducing the single analysis time from several tens of minutes or hours to a few minutes.The analysis is simple, saves time and costs, and is more environmentally friendly. Abstract A paper spray mass spectrometry (PS‐MS) method for rapid and reliable analysis of benzalkonium chloride (BAC) in compound eye drops and body surface disinfectant was developed. The sample was dropped onto triangular filter paper, and high voltage (3.5 kV) was applied to form an electrospray. This method can provide the composition of benzalkonium chloride in samples without pretreatment, solvent or chromatographic separation, and the analysis time is only 10 s. The primary homologues C12‐BAC, C14‐BAC and C16‐BAC of benzalkonium chloride were quantitatively analyzed using PS‐MS. Samples were subjected to simple dilution and quantified using the internal standard method. Ion trap mass spectrometry was scanned using SIM mode. The linear ranges of C12‐BAC, C14‐BAC and C16‐BAC were 1–100 &mgr;g mL−1; the linear regression coefficients were 0.998–0.999; the detection limits (LODs) were 0.1 &mgr;g mL−1; the limit of quantifications (LOQs) was <1 &mgr;g mL−1, and the method validation indicated that the method precision and accuracy were good. Compared with HPLC‐UV methods, there was no significant difference in the quantitative determination of the actual samples, but the analysis time for PS‐MS is shorter (2 min). In addition, reagent consumption in PS‐MS is small, and no chromatographic separation is needed, suggesting that PS‐MS is especially suitable for high‐throughput analysis.

Keywords: benzalkonium chloride; analysis; mass spectrometry

Journal Title: Journal of Pharmaceutical and Biomedical Analysis
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.