LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

A method using angiotensin converting enzyme immobilized on magnetic beads for inhibitor screening

Graphical abstract Figure. No Caption available. HighlightsA new screening method was developed by combining magnetic beads‐based enzyme immobilization and fluorescence detection.Achieving oriented enzyme immobilization by using anti‐FLAG antibody coated magnetic… Click to show full abstract

Graphical abstract Figure. No Caption available. HighlightsA new screening method was developed by combining magnetic beads‐based enzyme immobilization and fluorescence detection.Achieving oriented enzyme immobilization by using anti‐FLAG antibody coated magnetic beads in crude cell lysate.The immobilized enzyme was used directly for drug screening without cleavage to achieve high‐throughput profile. Abstract Angiotensin converting enzyme (ACE), fusing with FLAG tag, was overexpressed in human embryonic kidney 293T cells. This recombinant FLAG‐tagged ACE was immobilized on anti‐FLAG antibody coated magnetic beads by affinity method in crude cell lysate for the first time. The enzyme‐immobilized magnetic beads (ACE‐MB), without further cleavage procedure, were used directly to establish a cost‐effective and reliable method for screening ACE inhibitors by coupling with fluorescence detection. The enzymatic activity of the ACE‐MB was validated based on its Michaelian kinetic behavior towards hippuryl‐histidyl‐leucine by UHPLC‐MS/MS method firstly. Then, several conditions were optimized including amount of magnetic beads, incubation temperature and time in the procedure of ACE immobilization and amount of ACE‐MB in the microplate operation. Moreover, this screening assay was validated with Z′ factors between 0.71 and 0.81 using four known ACE inhibitors (captopril, lisinopril, fosinopril and fosinoprilat). The developed method was applied for the screening of ACE inhibitors from a small compound library of 45 natural products. As a result, epiberberine and fangchinoline with certain ACE inhibitory activities were screened out in the assay and validated. The results demonstrate the usefulness of this screening method using ACE immobilized on magnetic beads and the advantage of great efficiency with respect to both time and reagents for screening ACE inhibitors.

Keywords: immobilized magnetic; angiotensin converting; magnetic beads; ace; screening method

Journal Title: Journal of Pharmaceutical and Biomedical Analysis
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.