LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Modified pencil graphite electrode as a low-cost glucose sensor

Photo from wikipedia

Abstract A manganese oxides mediator was electrodeposited onto a low-cost pencil graphite electrode (PE) from an easily available and affordable potassium permanganate precursor. The modified manganese oxides coated PE (MnOxides/PE)… Click to show full abstract

Abstract A manganese oxides mediator was electrodeposited onto a low-cost pencil graphite electrode (PE) from an easily available and affordable potassium permanganate precursor. The modified manganese oxides coated PE (MnOxides/PE) was previously utilized as a hydrogen peroxide sensor according to its electrocatalytic activity for hydrogen peroxide oxidation in an ammonium buffer (pH 9.0) medium. The amperometric detection of hydrogen peroxide is possible at +0.50 V vs Ag/AgCl instead of +0.80 V vs Ag/AgCl using an unmodified PE. Further modification of the MnOxides/PE with glucose oxidase immobilization converted the modified PE into a glucose sensor by hydrogen peroxide detection in a phosphate buffer (pH 7.4) at the same operating potential. The linear concentration range of glucose detection by the batch technique was 0.056–1.41 mM, with a sensitivity of 2.19 μA mM−1. A detection limit of 18.3 μM and a percentage RSD of 5.0% were obtained from five different sensors. Through the flow injection analysis technique, a low-cost open-flow cell containing a volume of 1.4 mL was fabricated from a plastic vial and a micropipette tip. Using the injection volume of 200 μL and flow rate of 1 mL min−1, the linear concentration range of glucose detection was determined to be 0.56–5.55 mM, with the sensitivity of 0.72 μA mM−1, the detection limit of 0.29 mM, the response time of 20 s, and sample throughput of 34 samples per hour. The application of the proposed sensor to detect glucose in sport and energy drink samples showed good precision, with the percentage RSD of 0.7–5.6% (n = 3) and a recovery percentage of 97–103%.

Keywords: detection; graphite electrode; pencil graphite; low cost; sensor

Journal Title: Journal of Science: Advanced Materials and Devices
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.