LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Comparative analysis of 2 glenoid version measurement methods in variable axial slices on 3-dimensionally reconstructed computed tomography scans.

Photo from wikipedia

BACKGROUND Most glenoid version measurement methods have been validated on 3-dimensionally corrected axial computed tomography (CT) slices at the mid glenoid. Variability of the vault according to slice height and… Click to show full abstract

BACKGROUND Most glenoid version measurement methods have been validated on 3-dimensionally corrected axial computed tomography (CT) slices at the mid glenoid. Variability of the vault according to slice height and angulation has not yet been studied and is crucial for proper surgical implant positioning. The aim of this study was to analyze the variation of the glenoid vault compared with the Friedman angle according to different CT slice heights and angulations. The hypothesis was that the Friedman angle would show less variability. MATERIALS AND METHODS Sixty shoulder CT scans were retrieved from a hospital imaging database and were reconstructed in the plane of the scapula. Seven axial slices of different heights and coronal angulations were selected, and measurements were carried out by 3 observers. RESULTS Mid-glenoid mean version was -8.0° (±4.9°; range, -19.6° to +7.0°) and -2.1° (±4.7°; range, -13.0° to +10.3°) using the vault method and Friedman angle, respectively. For both methods, decreasing slice height or angulation did not significantly alter version. Increasing slice height or angulation significantly increased anteversion for the vault method (P < .001). Both interobserver reliability and intraobserver reliability were significantly higher using the Friedman angle. CONCLUSION Version at the mid and lower glenoid is similar using either method. The vault method shows less reliability and more variability according to slice height or angulation. Yet, as it significantly differs from the Friedman angle, it should still be used in situations where maximum bone purchase is sought with glenoid implants. For any other situation, the Friedman angle remains the method of choice.

Keywords: slice; version; glenoid version; version measurement; vault; friedman angle

Journal Title: Journal of shoulder and elbow surgery
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended