LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Osteosynthesis of type III acromial fractures with locking compression plate, lateral clavicular plate, and reconstruction plate: a biomechanical analysis of load to failure and strain distribution.

Photo from wikipedia

BACKGROUND Acromial stress fractures following reverse shoulder arthroplasty have been increasingly studied because of potential functional impairment caused by this complication. The purpose of this study was to evaluate and… Click to show full abstract

BACKGROUND Acromial stress fractures following reverse shoulder arthroplasty have been increasingly studied because of potential functional impairment caused by this complication. The purpose of this study was to evaluate and compare different plating techniques for a type III acromial fracture (also referred to as "scapular spine fracture") in a biomechanical setting with special regard to primary stability and modes of failure. METHODS Type III acromial fractures were simulated on 19 Sawbones scapulae and plated with either a lateral clavicular plate (LatCP), a locking compression plate (LCP), or a reconstruction plate (RecoP). We performed testing on 5 scapulae for each plate according to a staircase protocol (100 cycles each step): 50 N and 100 N, then increasing 100 N each step up to 800 N or until failure. The last series of mechanical tests included 3-dimensional micro-motion analysis. RESULTS The average force needed to cause failure of the osteosynthesis construct was 376 N for the LatCP, 506 N for the LCP, and 360 N for the RecoP. The difference between the LCP and RecoP was significant (P = .047). The average displacements of the acromion were 12.1 mm, 13.4 mm, and 11.7 mm, respectively. The spring constant was not significantly different between the plates. The LatCP showed increased strain medially, whereas the strain on the RecoP was spread more laterally. The LCP presented a balanced strain distribution, spread evenly over the fracture line. CONCLUSIONS In a biomechanical setting, the LCP showed superiority over the LatCP and RecoP as stabilization hardware for type III acromial fractures.

Keywords: acromial fractures; iii acromial; plate; failure; type iii

Journal Title: Journal of shoulder and elbow surgery
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.