LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Outcomes of a novel upper extremity preloaded delivery system for fenestrated-branched endovascular repair of thoracoabdominal aneurysms.

Photo from wikipedia

OBJECTIVE The aim of this study was to evaluate the feasibility and outcomes of endovascular repair of thoracoabdominal aortic aneurysms (TAAAs) using a novel low profile (LP) device with upper… Click to show full abstract

OBJECTIVE The aim of this study was to evaluate the feasibility and outcomes of endovascular repair of thoracoabdominal aortic aneurysms (TAAAs) using a novel low profile (LP) device with upper extremity preloaded guidewire system (PGS) and compare procedural metrics and outcomes with a standard multibranch stent graft (t-Branch; Cook Medical, Bloomington, Ind). METHODS We reviewed the clinical data of 232 consecutive patients treated by fenestrated-branched endovascular aortic repair for TAAA and enrolled in a prospective nonrandomized trial between 2014 and 2017. Patients who had repair using t-Branch or patient-specific TAAA devices using upper extremity LP-PGS were included. End points were technical success, operative and fluoroscopic time, patient radiation exposure, time from arterial access to complete device deployment, total contrast volume, and 30-day rates of major adverse events (MAEs) and mortality. RESULTS There were 54 patients, including 33 males (67%) and 21 females (33%), with a mean age of 73 ± 9 years old. Forty-nine patients (91%) had extent I-III and five patients (9%) had extent IV TAAAs. Device design was t-Branch in 24 patients (44%) and LP-PGS in 30 patients (56%). A total of 206 renal-mesenteric arteries were incorporated with no difference between groups (mean, 3.8 ± 0.6 target vessels/patient; P = .92). Patients treated by t-Branch device had larger mean aneurysm diameter (79 ± 16 vs 66 ± 10 mm; P = .0006). All patients had transbrachial approach. Technical success was achieved in all patients in both groups. Patients treated by LP-PGS devices had lower radiation dose (1250 ± 849 vs 3154 ± 2421 mGy; P = .003) and shorter operating time for complete device deployment (105 ± 42 vs 123 ± 34 minutes; P = .043). There was no difference in mean operative time (252 ± 69 vs 273 ± 56 minutes; P = .23), fluoroscopy time (82 ± 29 vs 96 ± 35 minutes; P = .08) or contrast volume (163 ± 59 vs 197 ± 75 mL; P = .07) comparing LP-PGS and t-Branch respectively. There was no 30-day or in-hospital mortality. There were no differences in MAEs, which occurred in 18 patients (33%) in both groups (P > .05). CONCLUSIONS Endovascular TAAA repair using the standard or LP-PGS multibranch stent graft was associated with high technical success, no mortality, and a low rate of MAEs in this study. Patients treated by upper extremity LP-PGS had shorter time to complete device deployment, suggesting decreased technical demand with preloaded systems.

Keywords: time; pgs; device; upper extremity; repair

Journal Title: Journal of vascular surgery
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.