OBJECTIVE The incidence of perigraft hygroma (PGH) development after aortic reconstruction remains poorly defined and its clinical relevance is questionable. This study was designed to establish the incidence of and… Click to show full abstract
OBJECTIVE The incidence of perigraft hygroma (PGH) development after aortic reconstruction remains poorly defined and its clinical relevance is questionable. This study was designed to establish the incidence of and determine the risk factors associated with PGH formation and its outcomes. METHODS Patients who underwent open aortic reconstruction for either aneurysmal or occlusive disease with an expanded polytetrafluoroethylene (ePTFE) or polyester graft from 2004 to 2018 were retrospectively reviewed (n = 262). Only those who had follow-up imaging 3 or more months after repair were included. Patients with mixed graft types were excluded. PGH was defined as a perigraft fluid collection of 30 mm or greater in diameter with a radiodensity of 30 or fewer Hounsfield units on computed tomography at a minimum of 3 postoperative months. Analysis was conducted between patients with and without PGH. RESULTS One hundred forty patients met the inclusion criteria: 88 were treated with ePTFE and 52 with polyester grafts. Twenty-three patients (16.4%) were found to have radiologic evidence of PGH. PGH developed more frequently in patients with ePTFE (21/88 [23.9%]) compared with those with polyester grafts (2/52 [3.8%]) (P = .002). Mean PGH size was 63.5 ± 36.4 mm (range, 33-153 mm) and the average time to PGH detection 27.7 months (range, 3-112 months). Baseline characteristics were similar between the groups. Patients who developed PGH had larger aneurysms, more often received ePTFE grafts, had larger graft diameters, and had bifurcated grafts. The overall mortality was 32.1% at a mean follow-up of 5.2 years. The 5-year mortality rates were similar between patients with and without PGH (26.1% vs 18.8%; P = .41). Of the 23 patients with PGH, 4 (all with ePTFE) presented with symptoms related to the PGH. The average size of symptomatic and asymptomatic PGH were 11.5 and 4.8 cm, respectively. Mortality rates overall were similar between those with and without symptoms (50.0% vs 36.8%; P = .99). CONCLUSIONS Nearly one-quarter of aortic reconstructions with ePTFE are associated with PGH formation compared with 4% with polyester. Clinically significant PGH-related symptom development occurs in 20%. Patient education and close surveillance are warranted. Manufacturer's device modification is needed.
               
Click one of the above tabs to view related content.