LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Design and development of a laser interferometer for magnet alignment and phase error analysis in an undulator

Photo from wikipedia

Abstract In this paper we discuss design and development of a laser interferometer for undulator measurement application. The vertical misalignment of the magnets in the undulator results in non uniformity… Click to show full abstract

Abstract In this paper we discuss design and development of a laser interferometer for undulator measurement application. The vertical misalignment of the magnets in the undulator results in non uniformity in the undulator gap and leads to non uniform magnetic field along the length of the undulator. The non uniformity in the magnetic field gives rise to trajectory wander and phase error. The trajectory wander and the phase error are the source of reduction in spontaneous emission and free electron laser gain. The effect is more severe for free electron lasers operating at higher harmonics. It is demonstrated that the laser interferometer can be used effectively to measure and correct the magnet alignments of the undulator.

Keywords: laser interferometer; laser; undulator; phase error

Journal Title: Measurement
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.