LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Diffusion MRI using two-dimensional single-shot radial imaging (2D ss-rDWI) with variable flip angle and random view ordering.

Photo by brnkd from unsplash

PURPOSE The main objective of this study is to develop a 2D single-shot radial-DWI (2D ss-rDWI) technique to reduce motion artifacts and geometric distortion in DW images. METHOD A diffusion-preparation… Click to show full abstract

PURPOSE The main objective of this study is to develop a 2D single-shot radial-DWI (2D ss-rDWI) technique to reduce motion artifacts and geometric distortion in DW images. METHOD A diffusion-preparation module is developed and applied prior to the data acquisition. Because the diffusion-prepared longitudinal magnetization is measured over multiple RF excitations in each shot, 2D ss-rDWI is subject to low signal-to-noise ratio (SNR). We used variable-flip angle (VFA), random view ordering (RVO), and sliding spokes, and compared the performances to constant flip angle (CFA), smooth view ordering (SVO), and identical spoke averaging, respectively. For each technique, we performed numerical simulation and MRI experiments on a fluid phantom as well as in-vivo human brain studies with a 3 T MRI system. RESULTS Using VFA, optimal SNR was acquired for 2D ss-rDWI. Using SVO, the high signal is clustered at specific quadrant in 2D k-space: the first quadrant using high initial flip angle or the last quadrant using the low flip angle. This clustered signal in k-space led to geometric distortion in image space. 2D ss-rDWI using RVO spreads the high signaled spokes over all angular directions and removes the view-order-related distortion. The in-vivo images using 2D ss-rDWI with VFA and RVO show no geometric distortion at the skull base brain, but greatly reduced SNR compared with those using 2D ss-DWEPI. CONCLUSION 2D ss-rDWI is optimized by using VFA with RVO. The resultant DWI using 2D ss-rDWI is insensitive to motion-induced artifacts and geometric distortion. Even with low SNR, it may be useful for DWI of organs limited by severe susceptibility-induced geometric distortion.

Keywords: flip angle; flip; view; distortion; rdwi

Journal Title: Magnetic resonance imaging
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.