LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Comparison of LIBS results on ITER-relevant samples obtained by nanosecond and picosecond lasers

Photo by testalizeme from unsplash

Abstract ITER foresees applying laser induced breakdown spectroscopy (LIBS) as a tool for quantitative assessment of fuel retention in the first walls. One open problem related to LIBS application is… Click to show full abstract

Abstract ITER foresees applying laser induced breakdown spectroscopy (LIBS) as a tool for quantitative assessment of fuel retention in the first walls. One open problem related to LIBS application is the choice of the laser type. Here we compare two Nd/YAG lasers with different pulse durations, 0.15 and 8 ns, working at λ = 1064 nm for LIBS studies of samples with D -doped W/Al coatings of ≈ 3 μm thickness (Al is used as a proxy of Be) on Mo. Low pressure argon was used as a background gas. Experiments were done in conditions where other factors (broadening of spectral lines, signal-to-noise ratio, limited thickness of coatings etc.) did not shadow the effect of laser pulse duration. For these reasons, low pressure argon was used as the background gas and fluences were kept at comparatively low values. Spectra of laser-produced plasma were recorded as a function of the number of laser pulses. Partially overlapping lines of hydrogen isotopes were fitted with Voigt contours, intensities were fitted and depth profiles of deuterium were reconstructed. The relative standard error of curve-fitting of spectra recorded with the laser of shorter pulse duration was two times smaller than that recorded by the longer pulse laser. The electron density was found from the Stark broadening of Hα line of the laser-produced plasma and the electron temperature of plasma was found on the basis W and Mo lines. It was found that in the case of ps laser an acceptable accuracy of the detection of deuterium was possible at considerably lower values of fluence. Steps needed for comparison of ps and ns lasers in ITER-relevant conditions were discussed.

Keywords: libs results; iter relevant; relevant samples; laser; results iter; comparison libs

Journal Title: Nuclear Materials and Energy
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.