LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

The Application of Infrared Imaging and Optical Coherence Tomography of the Lacrimal Punctum in Patients Undergoing Punctoplasty for Epiphora.

Photo by sharonmccutcheon from unsplash

PURPOSE To determine the application of imaging the stenotic lacrimal punctum with infrared photographs and optical coherence tomography (OCT) and to identify characteristics of the lacrimal punctum in patients who… Click to show full abstract

PURPOSE To determine the application of imaging the stenotic lacrimal punctum with infrared photographs and optical coherence tomography (OCT) and to identify characteristics of the lacrimal punctum in patients who benefit from punctoplasty. DESIGN Case-control study. PARTICIPANTS Twenty patients with epiphora who were listed for punctoplasty and 20 healthy controls. METHODS Prospectively, 20 patients listed for punctoplasty were asked to rate their epiphora, using the Munk score, before and after punctoplasty. They also underwent preoperative OCT and infrared imaging of the affected punctum. They were divided into 2 groups, depending on whether the epiphora improved, and were compared with 20 healthy controls. MAIN OUTCOME MEASURES Measurements of puncta from infrared and OCT images were obtained along with Munk scores of patient epiphora. RESULTS The infrared image measurements were significantly smaller in those patients whose epiphora improved compared with those whose did not in both the area of the punctal aperture and in the maximum punctal diameter. Additionally, those patients with improvement in epiphora had a significantly smaller preoperative punctal diameter at 100 μm depth on OCT compared with healthy controls; this was not observed in patients whose epiphora failed to improve. There was no significant difference in the punctum diameter among the 3 groups at the punctum surface entrance or at 500 μm depth. Patients with epiphora had a higher tear meniscus within the punctum compared with healthy controls. CONCLUSIONS Lacrimal punctum infrared and OCT imaging may be helpful in predicting patients more likely to benefit symptomatically from punctoplasty, with patients with smaller puncta having greater symptomatic improvement. However, the results suggest that inner punctum diameter (not readily measurable by slit-lamp examination), rather than the surface diameter, is correlated with outcome. Additionally, OCT measurements of the tear meniscus height within the punctum may be related to the degree of epiphora.

Keywords: punctum; optical coherence; punctum patients; coherence tomography; lacrimal punctum; diameter

Journal Title: Ophthalmology
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.