LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Evaluating the interchangeability of forehead, tympanic, and axillary thermometers in Italian paediatric clinical settings: Results of a multicentre observational study.

Photo from wikipedia

PURPOSE This study was conducted to investigate the interchangeability of infrared forehead, digital axillary, and infrared tympanic thermometers while identifying the most reliable non-invasive body temperature measurement method in paediatric… Click to show full abstract

PURPOSE This study was conducted to investigate the interchangeability of infrared forehead, digital axillary, and infrared tympanic thermometers while identifying the most reliable non-invasive body temperature measurement method in paediatric settings. DESIGN AND METHODS A multicentre observational study was conducted enrolling all children less than or equal to 14 years of age requiring a temperature measurement and after obtaining their parent's informed consent. Socio-demographic characteristics and temperature values in Celsius (°C) were simultaneously collected using forehead, axillary, and tympanic thermometers. RESULTS A total of 433 children were enrolled, 57.5% were male and the mean age was 5.3 ± 3.9 years. The average value of tympanic temperature (37.05 °C) was higher than forehead (36.87 °C) and axillary (36.8 °C). The mean difference between axillary and forehead temperatures (-0.06 °C) was not statistically significant (p = 0.158). Comparing the measurements of each type of thermometer with the overall average of the three measurements recorded as the virtual gold standard, Bland Altman analysis highlighted tympanic with narrower 95% limits of agreement (+0.96 °C to -0.68 °C). The tympanic thermometer also had the highest percentage (81.6%) of differences falling within the maximum clinically acceptable difference (±0.5 °C). CONCLUSIONS Differences between paired measurements of the three investigated devices demonstrated the devices are not interchangeable. Measurements using the tympanic thermometer more closely resembled the reference temperature indicating its preferential use in paediatric clinical practice. PRACTICE IMPLICATIONS To safely and consistently measure body temperature, nurses should not assume peripheral thermometers are interchangeable. It is essential to clinically validate all temperature values with clinical observations.

Keywords: observational study; temperature; study; interchangeability; paediatric clinical; multicentre observational

Journal Title: Journal of pediatric nursing
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.