OBJECTIVE The P300 ERP component is a marker of reduced capacity in alcohol use disorder (AUD) to engage attentional mechanisms and update memory representations. No meta-analysis to date has been… Click to show full abstract
OBJECTIVE The P300 ERP component is a marker of reduced capacity in alcohol use disorder (AUD) to engage attentional mechanisms and update memory representations. No meta-analysis to date has been completed comparing effect size estimates of auditory vs. visual stimuli in AUD. In addition, there is a lack of consensus on whether the P3b in women is reduced, or whether the P3a - an earlier, more frontally distributed component - is reduced in AUD. METHODS Strict inclusion criteria and data-analysis plans were implemented. Eligible studies needed to diagnose AUD using DSM and exclude patients with any psychiatric co-morbidities. Data analysis was completed using a refined variance estimator of the random effects model. RESULTS Effect size estimates were large for both auditory (Hedges' g = 1.01, p = .056) and visual (Hedges' g = 0.77, p = .040) P300 amplitudes, but only marginally significant for the auditory modality. Auditory P300 latency was significantly increased in AUD patients (Hedges' g = 0.73, p = .027). The moderator analysis did not show significant sex differences for either auditory (p = .97) or visual (p = .45) P3b. Finally, the P3a was not reduced in patients with AUD (Hedges' g = 1.01; p = .59). CONCLUSION This meta-analysis clarifies important questions related to P300 in AUD. By resolving inconsistencies, it is hoped that this information will facilitate the design of future studies.
               
Click one of the above tabs to view related content.