This study aims at offering a techno-economic evaluation of closed OTEC cycles for on-shore installations. A flexible Matlab® suite has been developed to identify plant design parameters (temperature difference of… Click to show full abstract
This study aims at offering a techno-economic evaluation of closed OTEC cycles for on-shore installations. A flexible Matlab® suite has been developed to identify plant design parameters (temperature difference of cold and warm seawater, pinch-point temperature difference of evaporator and condenser etc.) that guarantee the maximum value of γ (ratio between electricity output and heat exchangers area). The optimization model is able to handle different working fluids through the addition of specific correlations that consider fluid influence on heat transfer coefficients and turbine performance. Each plant component is technically analyzed and, in particular, plate heat exchangers were considered for evaporator and condenser and sized accurately with Aspen EDR®, while expander was analyzed with the in-house code Axtur. For warm seawater temperature of 28 °C and cold seawater temperature of 4 °C (8500 kg/s taken from 1000 m depth), ammonia cycle is the best solution characterized by efficiency equal to 2.2% and net power output equal to 2.35 MWe.
               
Click one of the above tabs to view related content.