LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Assessing the validity of two-dimensional carotid ultrasound to detect the presence and absence of a pulse.

Photo from wikipedia

BACKGROUND Traditional assessment of return of cardiac output in cardiac arrest by manual palpation has poor accuracy. Point of care ultrasound of a major artery has been suggested as an… Click to show full abstract

BACKGROUND Traditional assessment of return of cardiac output in cardiac arrest by manual palpation has poor accuracy. Point of care ultrasound of a major artery has been suggested as an alternative. We conducted a diagnostic accuracy study of two-dimensional carotid ultrasound to detect the presence or absence of a pulse, using cardiopulmonary bypass patients for pulse and pulseless states. METHODS A cross-sectional multi-patient, multi-reader repeated measures diagnostic study was conducted. For patients undergoing routine cardiopulmonary bypass, a portable ultrasound was used to record four 10-second videos the common carotid artery, three aimed for a pulse in high (>90 mmHg), medium (70-90 mmHg) and low (<70 mmHg) systolic blood pressure (SBP) ranges, and a pulseless video was recorded on cardiopulmonary bypass. Critical care physicians viewed the videos and were asked to nominate within 10 seconds if a pulse was present. True pulse-status was determined via the arterial-line waveform. RESULTS Twenty-three patients had all four videos collected. Median patient age was 64 (IQR 14), sixteen were male (70%) and median BMI was 27. The median SBP in high-, medium- and low-SBP groups were 120 mmHg, 83 mmHg and 69 mmHg respectively. Forty-six physicians reviewed a subset of 24 videos. Overall sensitivity was 0.91 (95% confidence interval 0.89-0.93) and specificity 0.90 (95% CI 0.86-0.93). Sensitivity was highest in the high-SBP group (0.96, 95% CI 0.93-0.98) and lowest in the low-SBP group (0.83, 95% CI 0.78-0.87). CONCLUSION 2D ultrasound of the common carotid artery is both sensitive and specific for detection of the presence or absence of a pulse.

Keywords: presence absence; absence pulse; carotid

Journal Title: Resuscitation
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.