While aerobic exercise training (AET) has generally been shown to improve 6-min walk test (6MWT) distance (6MWD) in patients with pulmonary hypertension (PH), a substantial number of patients appear to… Click to show full abstract
While aerobic exercise training (AET) has generally been shown to improve 6-min walk test (6MWT) distance (6MWD) in patients with pulmonary hypertension (PH), a substantial number of patients appear to adapt differently, with minimal or even negative changes in 6MWT distance being reported. PURPOSE To compare post-aerobic exercise training adaptations in cardiorespiratory functional capacity across three groups of patients with PH: those with high (HI), low (LI) and negative (NEG) post-training increases in 6MWD. METHODS Participants were 25 females (age 54 ± 11 years; BMI 31 ± 7 kg/m2) who completed a vigorous, 10-week, thrice weekly, supervised treadmill walking exercise program. Cardiopulmonary exercise tests (CPET) and 6MWT were completed before and after training. Ten of the 25 participants were classified as HI (range = 47-143 m), 11 were classified as LI (range = 4-37 m) and 4 were classified as NEG (range = -17 to -53 m). RESULTS Peak CPET duration, WR and time to anaerobic threshold (AT) were significantly higher (p < 0.05) after training in both the LI and HI groups but not in the NEG group. There was a significant improvement in VE/VCO2 (p = 0.042), PETCO2 (p = 0.011) and TV (p = 0.050) in the HI group after training, but not in the NEG or LI group. CONCLUSION These findings suggest that sustained ventilatory inefficiency and restricted respiratory buffering may mediate exercise intolerance and impede the ability to adapt to exercise training in some patients with PH.
               