Abstract This paper compares the two most common reflectometers used to assess the specular reflectance of back-silvered glass mirrors for Concentrating Solar Power (CSP) applications, namely the Device and Services… Click to show full abstract
Abstract This paper compares the two most common reflectometers used to assess the specular reflectance of back-silvered glass mirrors for Concentrating Solar Power (CSP) applications, namely the Device and Services (D&S) 15R-USB and the Abengoa Condor SR-6.1 instruments. Comparisons are first made between the two instruments themselves using a Gage Repeatability and Reproducibility (R&R) study. Results are given for the as-cleaned collector mirrors and then as the mirrors become naturally soiled over a one month period. The results of the Gage R&R study show that for the D&S the gage itself contributes 40.97% of the variability, whilst 59.03% is due to part-to-part (location on the mirror under investigation) variability. For the Condor we show that the % Contribution from the gage is 62.18% of the total variability with only 37.82% of the contribution attributable to the location dependent reflectance. The Condor has a wider acceptance angle, and over the reflectance range of 0.91–0.95 the condor was found to measure higher than the D&S by an average of 1.53%. The differences between the soiling results obtained from the two instruments are explained, and the results are used to derive a predictive model for the soiling of solar collectors. In conclusion, both instruments have advantages and shortcomings, and the factors that influence which instrument to select are discussed.
               