LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Ionic-liquid doped polymeric composite as passive colorimetric sensor for meat freshness as a use case.

Photo from wikipedia

A composite membrane containing 1,2-naphthoquinone-4-sulfonic acid sodium salt (NQS) embedded in an ionic liquid (IL)- polydimethylsiloxane (PDMS)- tetraethyl orthosilicate (TEOS)- SiO2 nanoparticles (NPs) polymeric matrix is proposed. The selected IL… Click to show full abstract

A composite membrane containing 1,2-naphthoquinone-4-sulfonic acid sodium salt (NQS) embedded in an ionic liquid (IL)- polydimethylsiloxane (PDMS)- tetraethyl orthosilicate (TEOS)- SiO2 nanoparticles (NPs) polymeric matrix is proposed. The selected IL was 1-methyl-3-octylimidazolium hexafluorophosphate (OMIM PF6). It is demonstrated that ILs chemical additives of PDMS influenced the sol-gel porosity. The sensor analytical performance for ammonia atmospheres has been tested as a function of sampling time (between 0.5 and 312 h), temperature (25 °C and 4 °C) and sampling volume (between 2L and 22 mL) by means of diffuse reflectance measurements and sensor photos, which can be registered and saved as images by a smartphone, which permit RGB measurements too. Flexible calibration was possible, adapting it to the sampling time, temperature and sampling volume needed for its application. Calibration linear slopes (mA vs ppmv) between 1.7 and 467 ppmv-1 were obtained for ammonia in function of the several studied conditions. Those slopes were between 48 and 91% higher than those achieved with sensors without ILs. The practical application of this sensing device was demonstrated for the analysis of meat packaging environments, being a potential cost-effective candidate for in situ meat freshness analysis. NQS provided selectivity in reference to other family compounds emitted from meat products, such as sulphides. After 10 days at 4 °C ammonia liberated by the assayed meat was 20 ± 4 μg/kg and 18 ± 3 μg/kg, quantified by using diffuse reflectance and %R measurements, respectively. Homogeneity of the ammonia atmosphere was tested by using two sensors placed in two different positions inside the packages.

Keywords: ionic liquid; liquid doped; doped polymeric; meat freshness; meat

Journal Title: Talanta
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.