LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Evaluation of ELISA-based method for total anabaenopeptins determination and comparative analysis with on-line SPE-UHPLC-HRMS in freshwater cyanobacterial blooms.

Photo by nci from unsplash

Anabaenopeptins (APs) are bioactive cyanopeptides of emerging concern produced by cyanobacteria. The research for analytical development has recently gained in importance due to their abundance in toxic cyanobacterial blooms. A… Click to show full abstract

Anabaenopeptins (APs) are bioactive cyanopeptides of emerging concern produced by cyanobacteria. The research for analytical development has recently gained in importance due to their abundance in toxic cyanobacterial blooms. A new commercial enzyme-linked immunosorbent assay kit for the determination of total APs (APtot ELISA) has been released promising a rapid response with good cost efficiency for the routine monitoring of uncommon cyanopeptides. The present study explores the suitability of this new kit in comparison with a validated quantitative analytical method based on liquid chromatography coupled to mass spectrometry (LC-MS). The validation results were comparable with both methods for accuracy, precision, and calibration. Method detection limits were more sensitive using LC-MS specifically evaluated at 0.011 and 0.013 μg L-1 for AP-A and B respectively, compared to APtot ELISA evaluated at 0.10 μg L-1 for total of the two. For APtot ELISA, results were independent from the matrix; however, a systematic signal response was measured in blanks, requiring a blank subtraction in data treatment. Cross-reactivity of APtot ELISA was investigated by analyzing ten cyanopeptides selected for their abundance and diversity. Cyanopeptolin A (CP-A), nodularin-R (NOD), microcystin (MC)-RR, [Asp3]RR, and HilR showed cross-reactivity with an average overestimation going from 25 to 66%. Considering the contribution of cross-reactive cyanopeptides, thirteen lake samples out of fifteen showed higher concentrations using APtot ELISA with overestimation values up to 2261% compared to LC-MS. In light of this study results, LC-MS should still be preconized for the study and monitoring of APs when sensitivity and specificity are needed.

Keywords: aptot elisa; evaluation elisa; elisa based; determination; method; cyanobacterial blooms

Journal Title: Talanta
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.