LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Monitoring unfractionated heparin therapy. 4 hour-stability of anti-Xa activity in unspun citrated tubes.

Photo from wikipedia

Current guidelines recommend performing laboratory tests aimed at monitoring unfractionated heparin (UFH) treatments within a delay not exceeding 1 to 2 h(s) after sampling when blood is collected into citrated tubes.… Click to show full abstract

Current guidelines recommend performing laboratory tests aimed at monitoring unfractionated heparin (UFH) treatments within a delay not exceeding 1 to 2 h(s) after sampling when blood is collected into citrated tubes. As such a short delay could be an issue, we evaluated the potential impact of longer delays. For that purpose, two citrated tubes were obtained from patients on UFH: one was centrifuged and tested for anti-Xa activity and aPTT within 1 h after collection (T1 h) and one was stored for 4 h at room temperature (T4 h) before being processed. A total of 123 paired tubes were investigated. Anti-Xa activity was significantly lower at T4 h than at T1 h, with a mean bias, calculated according to Bland-Altman, of 0.05 IU/mL. Considering 0.30 to 0.70 IU/mL as the therapeutic range, there were 12 cases of discrepant test results (9.8%). Most of them being around the lower limit of the therapeutic range had no impact on patients' management. APTT was significantly shortened (p < 0.0001) at T4 h vs. T1 h, with a mean bias of -7.9 s. Considering anti-Xa correlated aPTT therapeutic range, 29 cases of discrepant test results (23.6%) were found, 10% would have induce dosage changes. The concordance between anti-Xa activities measured at T4 h and T1 h was excellent (kappa = 0.813) and good for aPTT (kappa = 0.661). In conclusion, extending the delay between blood collection and measurement of tests prescribed for monitoring UFH therapy up to 4 h was found to lead to a systematic reduction in both anti-Xa activity and aPTT in unspun citrated tubes. As changes at T4 h were limited and had few clinically relevance than the ones observed with aPTT testing, a 4 h-delay was found to be acceptable for anti-Xa activity. The maximum delay for aPTT should remain around 1-2 h as changes were more relevant.

Keywords: anti activity; monitoring unfractionated; delay; unfractionated heparin; citrated tubes; activity

Journal Title: Thrombosis research
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.