LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Implantation of Responsive Neurostimulation for Epilepsy Using Intraoperative Computed Tomography: Technical Nuances and Accuracy Assessment.

Photo from wikipedia

INTRODUCTION Implantation of responsive neurostimulation (RNS) system has been previously discussed in the literature but there is a paucity of data on target accuracy and the use of intraoperative imaging.… Click to show full abstract

INTRODUCTION Implantation of responsive neurostimulation (RNS) system has been previously discussed in the literature but there is a paucity of data on target accuracy and the use of intraoperative imaging. We describe our experience with 8 patients using intraoperative computed tomography (iCT) during implantation of the NeuroPace RNS system. METHODS A frame-based system was used. CT images were obtained and merged with preoperative magnetic resonance imaging and metabolic imaging studies to calculate target coordinates. An occipital entry point with a trajectory parallel to the hippocampus was planned. The leads were placed in the parahippocampal white matter circuitry. iCT images were obtained for immediate confirmation of lead accuracy. Images were computationally merged and superimposed on the magnetic resonance images and final coordinates of the distal contact were compared with the intended target. Targeting error was calculated in each axis as well as Euclidean distance. Preoperative and postoperative seizure frequency per month was used to evaluate outcomes. RESULTS Fifteen occipitotemporal leads were placed in 8 patients. The vector error means in the x, y, and z planes were 0.57 mm ± 0.44 mm, 0.71 mm ± 0.84 mm, and 2.23 mm ± 1.43 mm, respectively. The mean Euclidean distance error was 2.63 mm ± 1.32 mm. The z axis was found to have a significantly higher error [F2,42 = 12.955; P = 0.001] when compared with the x or y axes. The median preoperative and postoperative seizure frequency per month was 3.4 and 0.78 seizures, respectively. CONCLUSIONS Frame-based stereotactic implantation of the NeuroPace RNS system using iCT is feasible and allows for intraoperative target accuracy confirmation and correction.

Keywords: implantation responsive; computed tomography; responsive neurostimulation; using intraoperative; implantation; intraoperative computed

Journal Title: World neurosurgery
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.