Abstract In the present study, application of a single unit vibro-impact system is improved. For this reason, in the so-called “magnetic impact damper” the impact mass is replaced by a… Click to show full abstract
Abstract In the present study, application of a single unit vibro-impact system is improved. For this reason, in the so-called “magnetic impact damper” the impact mass is replaced by a permanent magnet, which moves in coil of gap enclosure. In the magnetic impact damper, wasting energy during inelastic contacts of masses and converting energy into electrical energy during the mass movement inside the coil, leads to suppress undesired vibrations. In this study it is shown that the magnetic impact dampers are not only good vibration suppressors but also they can harvest electrical energy. Effect of changing the main parameters of this system including gap size, load resistance and electromagnetic coupling coefficient is studied on the vibratory and energy behavior of the magnetic impact dampers. Finally using several user oriented charts, it is shown that energy-based and vibration-based design considerations can effectively improve application of the discussed vibro-impact system.