We present two cases of patients with iatrogenic femoral arteriovenous fistula who underwent successful embolisation using three-dimensional shape detachable coils. A 49-year-old male with Tetralogy of Fallot had arteriovenous fistula… Click to show full abstract
We present two cases of patients with iatrogenic femoral arteriovenous fistula who underwent successful embolisation using three-dimensional shape detachable coils. A 49-year-old male with Tetralogy of Fallot had arteriovenous fistula which developed from the common femoral artery to the femoral vein with an aneurysm and a 17-year-old female with single ventricle after total-cavo-pulmonary-connection had two arteriovenous fistulas which developed from the internal iliac artery to the femoral vein. A total of six and seven pieces of detachable coils were necessary for complete occlusion, respectively. No complications were recorded. The advantage of the detachable coil is a wide variation and repositioning until the coil achieves good stabilisation and an ideal configuration.
               