LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

One-Shot In Vitro Evolution Generated an Antibody Fragment for Testing Urinary Cotinine with More Than 40-Fold Enhanced Affinity.

Photo from wikipedia

Immunoassays for cotinine, a major nicotine metabolite, in the urine are useful for monitoring the degree of tobacco smoke exposure. However, hybridoma-based anti-cotinine antibodies lack sufficient binding affinity to perform… Click to show full abstract

Immunoassays for cotinine, a major nicotine metabolite, in the urine are useful for monitoring the degree of tobacco smoke exposure. However, hybridoma-based anti-cotinine antibodies lack sufficient binding affinity to perform practically sensitive measurements, and thus most cotinine assays still rely on polyclonal antibodies. Here, we describe the generation of a mutant single-chain Fv fragment (scFv) that was used in an enzyme-linked immunosorbent assay (ELISA) to determine urinary cotinine levels in passive smokers. A "wild-type" scFv (scFv-wt) with a Ka value of 2.7 × 107 M-1 (at 4 °C) was prepared by linking the VH and VL domains in a mouse anti-cotinine antibody. "One-shot" random mutagenesis on the scFv-wt gene by error-prone PCR generated mutant scFv genes, which were expressed on phage particles. Repeated panning directed toward mutants with slower off-rates selected scFv clones that showed improved sensitivity in an ELISA system. One of these mutants (scFv#m1-54) with five amino acid substitutions showed more than a 40-fold enhanced Ka (1.2 × 109 M-1 at 4 °C) and, thus, was used to monitor human urinary cotinine. A limited amount of soluble scFv was reacted with urine specimens (or cotinine standards) at 4 °C for 120 min in microwells on which cotinine residues had been immobilized. The midpoint of the dose-response curves under optimized conditions (0.27 ng/assay) was more than 100-fold lower than the ELISA results obtained using scFv-wt. The limit of detection (8.4 pg/assay) corresponded to 0.17 ng/mL urinary cotinine, which was satisfactorily low for testing the threshold levels for passive smoke exposure. The assay values for volunteers correlated with the values determined using a commercial assay kit. This study evidently showed the potential of a molecular breeding approach, in which simple in vitro evolution might generate superior antibody reagents as cloned proteins, overcoming the limited molecular diversity inherent to conventional immunization-based antibodies.

Keywords: urinary cotinine; vitro evolution; one shot; cotinine; scfv; fold enhanced

Journal Title: Analytical chemistry
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.