The experiment for the gaseous pvT property of HFO-1234ze(E) (trans-1,3,3,3-tetrafluoropropene) was conducted with the Burnett method. The temperature range is from 318 to 401 K and the pressure is up… Click to show full abstract
The experiment for the gaseous pvT property of HFO-1234ze(E) (trans-1,3,3,3-tetrafluoropropene) was conducted with the Burnett method. The temperature range is from 318 to 401 K and the pressure is up to 3899 kPa. The temperature standard uncertainty, pressure standard uncertainty, and density relative standard uncertainty were estimated to be 2.3 mK, 600 Pa, and 0.0008, respectively. The experimental data show good agreement with previous results. The HFO-1234ze(E) second and third virial coefficients were derived with the temperature range of 363–401 K.
               