LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Design and Fabrication of Silicon Nanowire-Based Biosensors with Integration of Critical Factors: Toward Ultrasensitive Specific Detection of Biomolecules.

Photo from wikipedia

As critical factors affecting the sensing performance of silicon nanowire (SiNW) biosensors, the structure, functional interface, and detection target were analyzed and designed to improve sensing performance. For an improved… Click to show full abstract

As critical factors affecting the sensing performance of silicon nanowire (SiNW) biosensors, the structure, functional interface, and detection target were analyzed and designed to improve sensing performance. For an improved understanding of the dependence of sensor structure on sensitivity, a simple theoretical analysis was proposed to predict the sensitivity of biosensors with different SiNW types, widths, and doping concentrations. Based on the theoretical analysis, a biosensor integrating optimized critical factors was designed and fabricated. Optimizations focusing on the following aspects are considered: (1) employing n-type SiNW and controlling the impurity doping concentration of SiNW at approximately 2 × 1016-6 × 1016 atoms/cm3 to obtain a suitable charge density, (2) minimizing the SiNW width to 16.0 nm to increase the surface area-to-volume ratio, (3) using a native oxide layer on SiNW as a gate insulator to transport the captured charge molecules closer to the SiNW surface, (4) modifying the SiNW surface by 2-aminoethylphosphonic acid coupling to form a high-density self-assembled monolayer for enhancing the stability bound molecules, and (5) functionalizing the SiNW with ovalbumin molecules for specifically capturing the target immunoglobulin G (IgG) molecules. The sensing performance was evaluated by detecting IgG with concentrations ranging from 6 aM to 600 nM and control experiments. The SiNW biosensor revealed ultrahigh sensitivity and specific detection of target IgG with a measured limit of detection of 6 aM. The integration of the critical SiNW biosensor factors provides a significant possibility of a rapid and ultrasensitive diagnosis of diseases at their early stages.

Keywords: detection; silicon nanowire; critical factors; specific detection; integration critical

Journal Title: ACS applied materials & interfaces
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.