LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Toward a Practical Impedimetric Biosensor: A Micro-Gap Parallel Plate Electrode Structure That Suppresses Unexpected Device-to-Device Variations

Photo from wikipedia

We propose a rational electrode design concept for affinity biosensors based on electrochemical impedance spectroscopy to substantially suppress unexpected device-to-device variations. On the basis that the uniformity of the current… Click to show full abstract

We propose a rational electrode design concept for affinity biosensors based on electrochemical impedance spectroscopy to substantially suppress unexpected device-to-device variations. On the basis that the uniformity of the current distribution affects the variation, a novel micro-gap parallel plate electrode (PPE) was developed, where two planar electrodes with edges covered with a SiO2 layer were placed face to face. The structure provides a uniform current distribution over the planar electrode surface and maximizes the contribution of the planar electrode surface to sensing. For a comparative study, we also fabricated a micro-structured interdigitated electrode (IDE) that has been widely adopted for high-sensitivity measurement, although its current is highly concentrated on the electrode edge corner. Protein G (PrG) molecules were immobilized on both electrodes to prepare an immunoglobulin G (IgG) biosensor on which the specific binding of PrG–IgG can occur. We demonstrated that the IgG sensor with the PPE has small device-to-device variations, in strong contrast to the sensor with the IDE having large device-to-device variations. The results indicate that the current distribution on the electrode surface is important to fabricating electrochemical impedance spectroscopy biosensors with small device-to-device variations. Furthermore, it was found that the PPE allows ultrasensitive detection, that is, the sensor exhibited a linear range from 1 × 10–13 to 1 × 10–7 mol/L with a detection limit of 1 × 10–14 mol/L, which is a record sensitivity at low concentrations for EIS-based IgG sensors.

Keywords: electrode; unexpected device; device variations; spectroscopy; device device; device

Journal Title: ACS Omega
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.