The definition of a hemodynamically significant ductus arteriosus

Photo by schluditsch from unsplash

A cause and effect relationship between a hemodynamically significant ductus arteriosus (DA) in premature infants and important shortand long-term morbidities remains unproven. Over 60 randomized controlled trials (RCTs) of patent… Click to show full abstract

A cause and effect relationship between a hemodynamically significant ductus arteriosus (DA) in premature infants and important shortand long-term morbidities remains unproven. Over 60 randomized controlled trials (RCTs) of patent DA (PDA) treatment have failed to demonstrate a reduction in important neonatal adverse outcomes, including intraventricular hemorrhage (IVH), necrotizing enterocolitis (NEC), chronic lung disease (CLD), death or neurodisability. Although the PDA is a plausible trigger for many of these complications, consensus is elusive with the recognition that causality has not been proven from the RCTs and the PDA may just be a common occurrence in this population. There are several reasons for the failure of RCTs to demonstrate an effect: (a) contamination of the control arm with open label PDA treatment; (b) difficulty in achieving PDA closure in a large number of infants in the treatment arm due to poor drug efficacy or inadequate drug delivery; and (c) sole focus on long-term neurodevelopment impairments with failure to recognize other significant preand post-discharge factors that can mitigate treatment effect (in either direction). However, the most important reason for lack of effect in those trials may lie in the heterogeneity and lack of clarity in characterizing the hemodynamic significance of the DA, determining the optimal treatment time, and identifying the “at-risk” population most likely to benefit from closure. Many studies have utilized arbitrary cutoffs of clinical and echocardiography parameters, unrelated to important shortand long-term outcomes, with an over-reliance on PDA diameter to determine significance. The concept of hemodynamic significance represents a complex interaction between several intrinsic and extrinsic factors, and quantification of this principle is a challenge in neonatal medicine. In order to characterize hemodynamic significance, several elements need to be considered: (1) PDA shunt volume assessment and its impact on the systemic and pulmonary circulations; (2) myocardial function evaluation, especially in considering how the heart handles the increased preload in the setting of potential myocardial ischemia secondary to impaired coronary artery perfusion; (3) antenatal and perinatal characteristics that can act as effect modifiers to either mitigate or exacerbate potential detrimental consequences of a shunt. Defining hemodynamic significance requires a thorough appraisal of all of these factors. There is an increasing realization that an accurate estimation of shunt volume, rather than intermittent and discreet measurements of ductal diameter, provides a more holistic assessment of the hemodynamic impact of a PDA. Flow across the PDA is governed by Poiseuille’s Law which states that: “At a constant driving pressure [the pressure gradients across the PDA], the flow rate of liquid through a tube is directly proportional to the fourth power of the radius of the tube and inversely proportional to the length of the tube and viscosity of the fluid.” In the setting of a PDA, the pressure gradients across the vessel, the length and diameter of the PDA and blood viscosity all constantly change over the first few days following birth. This makes direct determination of shunt volume extremely challenging. Echocardiography can be utilized to diagnose more than just the presence of a PDA, but also to estimate shunt volume by measuring surrogate echocardiographic markers of pulmonary over-circulation and systemic hypoperfusion. For example, a drop in celiac or mesenteric artery blood flow in the presence of PDA, despite a rising LV output (LVO), coupled with aortic run off all provide measures of systemic hypoperfusion. The left atrial-toaortic ratio (LA/Ao), the early passive filling to late active phase ratio (E/A), the interval between closure of the aortic valve and mitral valve (isovolumic relaxation time, IVRT), and LVO are quantifiable indices of pulmonary over-circulation that can aid the delineation of hemodynamic significance of the DA. Although there are important considerations with each marker (e.g., pseudonormalization of some indices from offloading of the left atrium with a patent foramen ovale or atrial septal defect), recent evidence has demonstrated no difference between the measures in the presence of a large (>2mm) atrial level shunt. Myocardial function is another important component of hemodynamic significance, but has often been forgotten in the assessment of a PDA and warrants further attention. Although much of the morbidity and mortality is related to the effects of the PDA on the systemic and pulmonary circulations, cardiac function is still an important driver in disease. The premature myocardium is characterized by systolic and diastolic dysfunction due to an inefficient contractile apparatus, a lack of compliant elastic and a preponderance of stiff fibrous tissue. In particular, diastolic dysfunction in the setting of increased preload can exacerbate the adverse consequences of increased pulmonary blood flow. Recent evidence from studies in premature infants has demonstrated the importance of left ventricular (LV) diastolic function in maintaining right ventricular (RV)–pulmonary artery (PA) coupling: an increase in afterload, results in an increase in myocardial contractility up to a certain threshold, beyond which any further increase in afterload results in compromised contractility (decoupling). The presence of LV diastolic compromise results in a reduction of this decoupling threshold. RV function cannot increase in the face of increased afterload in the presence of LV diastolic dysfunction due to pulmonary venous hypertension. This can have significant clinical implications with a recent study illustrating a relationship between diastolic dysfunction and the need for ventilation and occurrence of pulmonary hemorrhage in premature infants <29 weeks. This relationship was independent of important confounders such as gestational age and antenatal steroids. In the setting of a PDA, decoupling could be further exacerbated due to the inability of the stiff LV to accommodate an increasing pulmonary venous return. Recent evidence also suggests that infants with lower diastolic function assessed using tissue Doppler imaging are more likely to suffer from PDA-related morbidities such as CLD. This highlights the importance of considering LV diastolic function in the definition of hemodynamic significance.

Keywords: pda; treatment; effect; significance; function; hemodynamic significance

Journal Title: Pediatric Research
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.