LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Monitoring rate and predictability of intraoperative monitoring in patients with intradural extramedullary and epidural metastatic spinal tumors

Photo from wikipedia

Study design:Single-center retrospective study.Objectives:To evaluate the monitoring rate, sensitivity and specificity of intraoperative monitoring (IOM) during removal of intradural extramedullary (IDEM) or epidural metastatic spinal tumors. Also, to assess the… Click to show full abstract

Study design:Single-center retrospective study.Objectives:To evaluate the monitoring rate, sensitivity and specificity of intraoperative monitoring (IOM) during removal of intradural extramedullary (IDEM) or epidural metastatic spinal tumors. Also, to assess the efficacy of monitoring somatosensory-evoked potentials (SSEP) when motor-evoked potentials (MEP) are not measurable.Setting:The Neuro-Oncology Clinic, National Cancer Center, Korea.Methods:Patients (n=101) with IDEM or epidural metastatic spinal tumors at the cord level underwent surgeries monitored with SSEP and/or MEP. The monitoring rate was defined as negative when MEP or SSEP could not be measured after reversal of the neuromuscular block under general anesthesia. Positive IOM changes included more than a 50% change in the MEP or SSEP amplitude and more than a 10% delay in SSEP latency.Results:MEP was measurable in 73% of patients. The MEP monitoring rate in patients with motor power grades of 3 or less was 39%, which was lower than that of SSEP (83%). The sensitivity, specificity and predictability of MEP for motor changes were 93, 90 and 91%, respectively. Conversely, the sensitivity, specificity and predictability of SSEP were 62, 97 and 89%, respectively. In patients in whom MEP was not measurable (n=24), SSEP was monitored with a predictability of 83%.Conclusion:In cases of extramedullary spinal tumors, MEP shows a higher sensitivity than SSEP does. However, the monitoring rate of MEP in non-ambulatory patients was lower than that of SSEP. In those cases, SSEP can be useful to monitor for postoperative neurological deficits.

Keywords: predictability; epidural metastatic; monitoring rate; monitoring; spinal tumors

Journal Title: Spinal Cord
Year Published: 2017