Tetracycline (TC) is a broad-spectrum antibiotic. When humans consume too much food containing tetracycline residues, it can be a serious health hazard. Therefore, it is essential to develop a strategy… Click to show full abstract
Tetracycline (TC) is a broad-spectrum antibiotic. When humans consume too much food containing tetracycline residues, it can be a serious health hazard. Therefore, it is essential to develop a strategy to detect TC. In this study, we prepared light blue-green luminescent nitrogen-doped graphene quantum dots (N-GQDs) by a hydrothermal method using the natural products potato straight-chain starch and urea as precursors; the fluorescence quantum yield of the prepared N-GQDs was 5.2%. We investigated the detection of tetracycline (TC) by this N-GQD fluorescent sensor based on the internal filtration effect (IFE) of TC on N-GQDs. The reaction is green, simple and no other contaminating products are present. A good linear relationship was established between the relative fluorescence intensity ratio of the system and the logarithm of the TC concentration of 2.5 × 10−10 to 5 × 10−6 M (R2 = 0.9930), with a detection limit of 9.735 × 10−13 M. The method has been used to analyze TC in three real food samples (whole milk, skim milk, honey) with low detection limits (3.750 × 10−11 to 2.075 × 10−9 M), wide linear range, and satisfactory recoveries of 93.80–109.20% were obtained. In conclusion, the proposed method is a green, rapid, highly sensitive and selective method for the detection of tetracycline in real food samples, demonstrating the potential application of N-GQDs in food detection.
               