LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Visualizing the Consistency of Thickened Liquids With Simple Tools: Implications for Clinical Practice.

Photo from wikipedia

Purpose Accurate texture modifications to thin liquids are a critical aspect of patients' nutritional health and well-being. This study explored the use of 3 tools (2 distance- and 1 time-measuring… Click to show full abstract

Purpose Accurate texture modifications to thin liquids are a critical aspect of patients' nutritional health and well-being. This study explored the use of 3 tools (2 distance- and 1 time-measuring devices) to characterize texture-modified liquids. The objectives were to use the tools to measure modified liquids, to determine if measurements differentiated nectar and honey levels of modification, and to compare measurements with other published reports. Method We measured the flow distance of 33 prethickened water samples in centimeters (cm) using a line spread apparatus and a Bostwick Consistometer (Christison Particle Technologies). We selected a Zahn viscosity cup to measure the stream time of each prethickened liquid in seconds. Results The 2 distance-measuring devices (line spread and Bostwick Consistometer) showed that thinner (nectar-thick) modifications spread or flowed a farther distance in comparison to thicker (honey-like) modifications. Testing with the line spread indicated that an average spread distance of 4.5 cm differentiated nectar-thick and honey-like consistencies. A flow distance of greater than 15 cm differentiated nectar from honey consistency measured with a Bostwick Consistometer. We were not successful in using the Zahn viscosity cup to determine the stream time of modified liquids. Conclusions Two of the tools provided objective information about levels of liquid modification, which has implications for day-to-day preparation. Measurement tools that are accurate and easy to use have the potential to provide quick and dependable feedback to verify a prescribed level of liquid modification. Further efforts are needed to standardize the application of simple measurement tools in the management of patients who consume thickened liquids.

Keywords: differentiated nectar; distance; honey; consistency; modified liquids; thickened liquids

Journal Title: American journal of speech-language pathology
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.