LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Method to reduce an unwanted EM field component in a 4-port TEM cell

Photo by maihe from unsplash

As an alternative standard electromagnetic (EM) field generator, a 4-port TEM (transverse EM) cell can be used for an EM compatibility (EMC) emission and immunity test. However, unwanted EM fields… Click to show full abstract

As an alternative standard electromagnetic (EM) field generator, a 4-port TEM (transverse EM) cell can be used for an EM compatibility (EMC) emission and immunity test. However, unwanted EM fields generated in a TEM cell deteriorate the results and accuracy of critical EMC tests. A new method to suppress unwanted field components in a 4-port TEM cell is proposed. To reduce the unwanted EM field, the narrow slits in internal septa are inserted, which are transverse with respect to the direction of wave propagation. By introducing the slits, the 4-port TEM cell can provide improved standard EM field distribution with the much-lowered unwanted field component inside the usable test volume.

Keywords: tem cell; field; port tem; unwanted field; tem

Journal Title: Electronics Letters
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.