LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Perioperative Continuous Noninvasive Cardiac Output Monitoring in Cardiac Surgery Patients by a Novel Capnodynamic Method.

Photo by spit from unsplash

OBJECTIVES To test the clinical performance of a novel continuous noninvasive cardiac output (CO) monitoring based on expired carbon dioxide kinetics in cardiac surgery patients. DESIGN A prospective feasibility pragmatic… Click to show full abstract

OBJECTIVES To test the clinical performance of a novel continuous noninvasive cardiac output (CO) monitoring based on expired carbon dioxide kinetics in cardiac surgery patients. DESIGN A prospective feasibility pragmatic clinical study. SETTING A single-center, large community hospital. PARTICIPANTS Thirty-two patients undergoing cardiac surgery were studied during the intraoperative (before cardiopulmonary bypass) and postoperative (in the intensive care unit before extubation) periods. INTERVENTIONS CO was measured simultaneously by the continuous capnodynamic method and by transpulmonary thermodilution during changes in the patient's hemodynamic and/or respiratory conditions. MEASUREMENTS AND MAIN RESULTS The current recommended comparative statistics for CO measurement methods were analyzed, including bias, precision, and percentage error obtained from Bland-Altman analysis, and concordance between methods obtained from the four-quadrant plot analysis to evaluate the trending ability. Bias ± limits of agreement and percentage error were -0.6 (-1.9 to +0.8; 95% CI of 3.73-5.25) L/min and 31% (n = 147 measurements) for the intraoperative period, -0.8 (-2.4 to +0.9; 95% CI of 3.03-5.21) L/min and 41% (n = 66) for the postoperative period, and -0.6 (-2.1 to +0.8; 95% CI of 3.74-5.00) L/min and 34% (n = 213) for the pooled data. The trending analysis obtained a concordance of 82% (n = 65) for the intraoperative and 71% (n = 24) for the early postoperative periods. Aggregation of both data sets gave a concordance of 79% (n = 89). CONCLUSIONS The continuous capnodynamic method was reliable and in good agreement with the reference method, and had an accuracy and trending ability good enough to make it a possible future alternative for hemodynamic monitoring in the studied population of elective adult cardiac surgery patients.

Keywords: surgery patients; continuous noninvasive; surgery; capnodynamic method; cardiac surgery

Journal Title: Journal of cardiothoracic and vascular anesthesia
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.