LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Assessment of the Efficacy of Microinvasive Glaucoma Surgery Techniques using an Oculopression Stress Test.

Photo from wikipedia

BACKGROUND Glaucoma is one of the most common causes of blindness worldwide. The only evidence-based treatment to slow down the progression of glaucoma is the reduction of intraocular pressure (IOP)… Click to show full abstract

BACKGROUND Glaucoma is one of the most common causes of blindness worldwide. The only evidence-based treatment to slow down the progression of glaucoma is the reduction of intraocular pressure (IOP) using local medication or through surgery. During the last years, a large number of microinvasive glaucoma surgery techniques (MIGS) has been developed, in order to reduce the IOP in glaucoma patients safely and effectively. Until now, efficacy of MIGS has been assessed mainly according to the postoperative IOP and the number of medications used. Results from long-term studies are rare or not available in the majority of the cases. In order to better evaluate the functionality of MIGS, a new examination method has been developed with the help of a new oculopressor device. In this study the efficacy of different MIGS techniques will be examined using the new oculopressor. MATERIAL/METHODS At first, glaucoma patients that had previously received a MIGS surgery (iStent inject, XEN Stent, ELT) were examined with the new oculopression test. Their results were compared with those of non-operated patients and healthy individuals. Overall, 38 healthy subjects (group 1), 10 non-operated patients (group 2), 19 patients after iStent inject implantation (group 3), 14 patients after XEN Stent implantation (group 4) and 5 patients after ELT (group 5) were examined. The new examination measures the IOP-reduction that occurs after oculopression and can be seen as an indirect measurement of the outflow facility of the eye. RESULTS The IOP-reduction after oculopression differed among the study groups. Non-operated patients showed a significantly lower IOP-reduction compared to healthy individuals. Patients after iStent inject and XEN stent implantation showed a larger reduction of IOP after oculopression in relation to non-operated patients and their results approximated those of healthy individuals. These patients needed fewer medications postoperatively in relation to non-operated patients. Patients after ELT showed postoperatively a smaller reduction of IOP after oculopression compared to iStent inject and XEN stent patients. CONCLUSION MIGS can increase the outflow facility of the eye in patients with glaucoma. Though ELT had the lowest impact on the aqueous outflow among the studied procedures in this study. The new test can help in the evaluation of current and further development of new MIGS in the future.

Keywords: reduction; operated patients; glaucoma; iop; oculopression; non operated

Journal Title: Klinische Monatsblatter fur Augenheilkunde
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.